Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/09/2004 |
MECHANICAL - INTERMEDIATE |
|
Approved |
IVRS - Inspection :* |
| 06/08/2004 |
MECHANICAL - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :*/ 1) COPPER JOINTS NEED TO BE TAPED AROUND STEEL. 2) EX. FANS - 3½" X 8" TO 6" TRANSISTION - BAROMETRIC DAMPER IS NOT OPENING. NEED TO CLEAR AREA ABOVE SO FULL MOVEMENT IS POSSIBLE. |
| 06/07/2004 |
MECHANICAL - INTERMEDIATE |
|
Denied |
1) INSULATE AROUND FLEX DUCT CONNECTOR SUPPLY DUCT OFF AIR HANDLER. 2) ISOLATE ALL COPPER REFRIG LINES FROM STEEL. 3) ADJUST PLASTER GROUNDS ON SUPPLY reg. 4) pre boot face at access to strainers valves. 5) control wiring not in wall. 6) flex duct connector keep in alighnment. CHECKED ALL TAPED JOINTS. |