Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/12/2003 |
PLUMBING - ROUGH, SOIL |
|
Approved |
1) SOIL WTR TEST OK. 2) OK FOR BACKFILL. |
| 12/11/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) CANNOT USE A COMBO IN A VERTICAL POSITION FOR A TRAP ARM. THIS WILL CAUSE THE OUTLET OF TRAP TO BE LOWER THAN TRAP. USE A SAN-TEE 2) FERNCO COUPLINGS NOT ALLOWED UNDER THE STRUCTURE OR ON A NEW APPLICATION USE SPECIALTY COUPLING. 3) MUST PROVIDE WATER TEST ON WASTE AND VENT SYSTEM 4) MUST STRAP DOWN ALL HORIZONTAL VENTS ABOVE CEILING. NO P-TAPE ALLOWED. 5) FOR ADDRESS 1009 E. 32ND ST.: MUST EXPOSE COVERED PLUMBING 2) MUST STRAP DOWN HORIZONTAL VENTS |