Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/30/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 12/27/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SEE ALL ITEMS LAST INSPECTION, I TALKED TO MR. CARPENTER, HE IS GOING TO COMPLETE ITEMS |
| 12/23/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CANCELLED BY SUPER, NOT READY |
| 12/20/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) REMOVE 2 X 4'S ON ROOF DECK NAIL ALL LEDGERS AND BARGE/END NAILERS TO ROOF DECK 2) LAG BALCONY LEDGER 3) RUN SHEAR AT GABLE ENDS UP TO ROOF DECK SEE LAST INSPECTION FOR ANY OTHER ITEM |
| 12/19/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) 3 PT BEARING HIP GIRDER SHIM 2) RUN SHEAR IN GARAGE UP TO FLOOR DECK 3) SHEAR AT GARAGE EXTENSION TO GO TO ROOF 4) FINISH WIND BRACES 5) SHEAR BEHIND KITCHEN SOFFIT 6) LAG WALKING DECK LEDGER 7) ROOF NOT NAILED OFF YET, NAIL ALL PERIMETERS UNDER 2 X 4 PLANTED ON FOR ONE TIE, SEE LEDGER NAILING |