Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM05166
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/15/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
01/14/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) HTT16'S AND AB AT 24" ON CENTER 2) DOUBLE WEDGE AT 3 PT. BEARING GARAGE 3) MISSING #4 SHEARWALL, DRYWALL BACKING AT TUB DOWNSTAIRS 4) FLOOR BLOCKING PANELS BETWEEN FLOORS 9/A8 5) BANG PLATES UPSTAIRS BATH MASTER, VENT AND WATER LINES 6) NEED 1" CLEARANCE AROUND BACK VENT 7) NAILERS IN UPSTAIRS CLOSETS |