Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM05165
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/08/2003 | FRAMING | Approved | IVRS - Inspection 0000*/ 1) REINSPECTION OK | |
01/07/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) OK TO INSULATE 2) ADD SHEAR AT FURNACE TRUSSES GARAGE 3) FIX FLOOR PLY AT JOINTS 4) BANG PLATE DRYER DUCT AT POT SHELF | |
01/03/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) FIRE BLOCK TRIANGLE AZ COVE 2) LEAK IN SOIL LINE, RIGHT SIDE OF STAIR, NEED 1/4 PITCH PER FT FLAT VENT 3) PUT A HANDLE ON HOSE BIB DWV 4) # 5 SHEAR WALL 24" ON CENTER A.B. GARAGE 5) HALL BATH 1ST FLOOR FLEX MECH DUCT FEELS LIKE WATER INSIDE DUCT, CUT OUT TOP PLATES LIFT DUCT UP 6) FILL ALL HOLES LU210 HANGERS KITCHEN CEILING 7) FLEX EXHAUST DUCT NOT SECURED TO ROOF 2ND REAR BATH 8) 2ND FLOOR FURNACE PLATFORM NOT SECURE 9) PUT ROMEX INTO LIGHT BOX 2ND FLOOR HALL CEILING 10) GAS HOLDING 25 POUNDS | |
01/02/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) SHEAR BLOCKS AT GARAGE TO LIVING ROOM WALL 2) 24" ON CENTER REAR SHEAR #5 3) GAS PRESSURE OK 4) NAIL FLOOR PLY WHERE JOINTS ARE LOOSE 5) SHEAR TRANSFER AT 2ND FLOOR ROOF, IN CLOSETS NAIL BOTTOM OF OSB TO 2 X 4 NAILER 6) ADD BLOCKS AT SMALL GIRDERS 2ND FLOOR TO FILL ALL HOLES IN HANGERS WITH NAILS 7) LINE SETS IN GARAGE WALL STICK OUT BEYOND DRYWALL | |
12/31/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) DON'T FORGET SHEAR WALL IN GARAGE UNDER BEAM, DEN OPTION |