Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/19/2003 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 12/15/2003 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) FINISH CARPORT LIGHTING 2) RECEIVED LETTER FOR FEEDERS 3) IF CARPORTS ARE NOT FINISHED NEXT INSPECTION A REFEE MAY BE ISSUED |
| 12/08/2003 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) PLEASE PROVIDE A LETTER AUTHORIZING USE OF ALUMINUM FEEDER AND FINISH CARPORT LIGHTING |
| 12/03/2003 |
ELECTRIC - FINAL |
|
Partial Approval |
1) PLEASE PROVIDE LETTER AUTHORIZING USE OF ALUMINIUM FEEDER CONDUCTS 2) UF CABLE TO CARPORT LIGHTING WAS INSTALLED WITHOUT INSPECTION AT EXIT OF CABLE IT APPEARS TO ONLY BE 1"-2" BELOW SIDEWALK IT IS TO BE 6"-CABLE CANNOT BE USED 3) FINISH CARPORT LIGHTING 4) OK AT CENTER BETWEEN CANOPIES-OF CABLE OK TO CEMENT COVER AND BACK FILL |
| 11/28/2003 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) UF CABLE UNDER SIDEWALK ? NOT INSPECTED. NOT AVAILABLE FOR USE 2) SEE WRITE UPS FOR OTHER UNITS |