Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T02CM05106
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/19/2003 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
| 12/18/2003 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000*/ 1) TIGHTEN LOOSE FITTINGS 2) INSTALL MISSING JUNCTION BOX COVER 3) FINISH SUPPORTING M/C CABLE 4) CALL ALL INSPECTIONS ( BUILDINGS) IN | |
| 12/15/2003 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000*/ 1) FINISH CARPORT LIGHTING 2) RECEIVED LETTER FOR FEEDERS 3) IF CARPORTS ARE NOT FINISHED NEXT INSPECTION A REFEE MAY BE ISSUED | |
| 12/08/2003 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) PLEASE PROVIDE A LETTER AUTHORIZING USE OF ALUMINUM FEEDER AND FINISH CARPORT LIGHTING | |
| 12/03/2003 | ELECTRIC - FINAL | Partial Approval | 1) OK UF CABLE IN TRENCHES-OK TO CEMENT COVER AND BACKFILL 2) PLEASE PROVIDE LETTER FOR ALUMINIUM FEEDERS #3 OLD 3) FINISH CARPORT LIGHTING | |
| 11/28/2003 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000*/ 1) AN APPROVED EXTENDER RING IS NEEDED FOR BOXES NOT FLUSH IN COMBUSTIBLES-AT CABINETS 370.20 2) PLEASE UNLOCK WATER HEATERS FOR INSPECTION 3) PLEASE PROVIDE A LETTER AUTHORIZING USE OF ALUMINUM FEEDER CONDUCTORS 4) NO CABLE IN TRENCH 5) TIGHTEN LOOSE FITTINGS AND SUPPORT A/C DISCONNECT BOXES |