Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T02CM05106
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/16/2003 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection 0000*/ 1) OK GROUND CLIP/BARS IN BOXES | |
| 06/20/2003 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) OK ROUGH ELECTRIC 2) PLEASE FINISH #3 OF PREVIOUS INSPECTIONS | |
| 06/18/2003 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) PLEASE FINISH #2 AND 3 OF PREVIOUS INSPECTION 2) OK TO 1 SIDE ONLY | |
| 06/16/2003 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) MAINTAIN FIRE SEPERATION AT BATH LIGHTS 5/6 OUTLET BOXES 6/7 AND THROUGH PENETRATIONS 2) CLAMPING DEVICES FOR BOXES 2 GANG AND LARGER 370. 17 3) WHERE IS GROUNDING SUPPORT FOR 3/0 BOXES ? 4) SUPPORT VDV CABLE ON HORIZONTAL RUNS AT SERVICE |
|
| 06/13/2003 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999*/ 1) #7 WIRING IN BATHROOMS NOT FINISHED 2) PANEL TO BE SUPPORTED BOTH SIDES |