Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T02CM05100
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/13/2003 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
03/12/2003 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) GROUND STILL NOT INSTALLED-#2 ABOVE 2) LAUNDRY VENT FLAPPER STILL STUCK-#5 ABOVE 3) SUPPORT GAS PIPE TO FURNACE 4) MOVE FURNACE FLUE FROM TRUSS 5) CLEANOUT CONDENSATE PAN 6) CORRECT NEGATIVE PITCH ON PRIMARY CONDENSATE LINE | |
03/10/2003 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) NEED BACK FLOW VALVE ON FRONT HOSE BIB 2) UNCONNECTED #14 GROUND IN PANEL 3) COLOR HOT WHITE WIRE IN PANEL 4) MOVE A/C FROM IN FRONT OF DISCONNECT 5) LAUNDRY VENT FLAPPER IS STUCK |