Permit: T02CM05079

Parcel: 124080360


Addresses:

1517 E 8TH ST #01

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/06/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*
03/05/2003 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*ALL HORIZONTAL SECTION OF PVC TO BE SUPPORTED AN D OR STRAPPED.
2.) MINIMUM 2 PIPE DIAMETERS FROM WEIR OF TRAP TO POINT OF VENT.
03/02/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
1) OK TO INSULATE ALL OUTER WALLS-PLUMBING SUJECT TO WATER OR AIR TEST.
2) TRAP ARMS LOCATIONS - OK TO COVER