Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM05056
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/08/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
01/07/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SAME AS LAST INSPECTION | |
01/06/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) PUT GAS STUB IN A BOX 2) CHANGE HANGER FROM THA 418 TO 1465 POUNDS HGUS 26-2 3585 POUNDS USE ALL 16D COMMONS AT GARAGE FLOOR TRUSS TO GIRDER | |
01/03/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) BLOCK SINGLE STUD AT CORNER RIGHT SIDE FRONT DOOR INTERIOR 2) PUT GAS LINE TERMINATION IN A BOX ACCESSIBLE 3) SECURE CONDENSATE EAST WALL 4) BOX OUT SCUTTLE HOLE HVAC ACCESS 5) ALL SW4 PLYWOOD SHEARS TO HALLS A.B. AT 24" ON CENTER |