Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/05/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ OK FOR C OF O. |
| 08/04/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1) TRAP ARM CAN ONLY HAVE 1 - 90 DEGREE. IF YOU EXCEED 1 - 90 DEGREE, THEN A C.O. IS REQUIRED ON TRAP ARM. 1 - 90 DEGREE & 1 - 45 DEGREE = 135 DEGREE. |
| 08/01/2003 |
PLUMBING - FINAL |
|
Denied |
1) MUST USE A SAN-TEE FOR P.O.C. OF 2" TRAP ARM 2) CAN NOT CONNECT CONDENSATE DRAIN TO HAND SINK. TAKE THIS DRAIN AND INDIRECT IT TO MOP SINK |