Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM05047

Parcel: 141013500

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM05047

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/24/2003 FRAMING Approved IVRS - Inspection 0000*
02/21/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) OK TO INSULATE
02/20/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) BANG PLATE WATER SERVICE TOP PLATE 2) COUNTER, MOVE OUTLET FROM UNDER OVERHANGING TOP CAN USE A DOUBLE OUTLET AT WALL TO COUNTER INTERSECTION TO COMPLY WITH OUTLET SPACING REQUIRED 3) STAPLE IN SOLAR WATER LINES BOTTOM PLATES 4) TWO SHEAR WALLS WITHOUT VERTICAL NAILING AT PARTION INTERSECTIONS EAST SIDE, WALLS RUN EAST WEST 5) INSTALL STRAP AT BOTTOM PLATE GARAGE 6) GAS PRESSURE OK, DWV WATER OK
02/07/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) A.B. AT FRONT DOOR 2) BLOCK MECH DUCT LAUNDRY 3) DRAIN WASTE AND VENT WATER TEST