Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM05047
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/24/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/21/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) OK TO INSULATE | |
02/20/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) BANG PLATE WATER SERVICE TOP PLATE 2) COUNTER, MOVE OUTLET FROM UNDER OVERHANGING TOP CAN USE A DOUBLE OUTLET AT WALL TO COUNTER INTERSECTION TO COMPLY WITH OUTLET SPACING REQUIRED 3) STAPLE IN SOLAR WATER LINES BOTTOM PLATES 4) TWO SHEAR WALLS WITHOUT VERTICAL NAILING AT PARTION INTERSECTIONS EAST SIDE, WALLS RUN EAST WEST 5) INSTALL STRAP AT BOTTOM PLATE GARAGE 6) GAS PRESSURE OK, DWV WATER OK | |
02/07/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) A.B. AT FRONT DOOR 2) BLOCK MECH DUCT LAUNDRY 3) DRAIN WASTE AND VENT WATER TEST |