Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/05/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 12/31/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0950*/ 1) RED HEADS EXPANSION BOLTS NOT ALLOWED-SEE S-1 FOR PROPER RETRO FIT BOLTS 2) NO TRUSS DRAWINGS ON SITE 3) FLOOR JOIST HANGERS MISSING NAILS 4) GARAGE SHEAR WALL NOT NAILED 5) NAILING OF 6/SD2 NOT COMPLIED WITH |
| 12/26/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) AB 2) FLUE PIPE FOR WATER HEATER LOOSE 3) 1" MINIMUM FOR FIRE BLOCKING 4) NO WATER AT TOP OUT TEST |
| 12/19/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 12/18/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |