Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM05015
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/05/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
12/04/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) NAIL OFF ROOF AT SOUTHWEST CORNER 2) BLOCK AND NAIL OFF OSB THAT COVERS ONE BAY (2 TRUSSES) ON FRONT LOWER ROOF 3) NAIL OFF H2.5'S AT PATIOR GIRDER 4) CLIP PATIO ROOF LEDGER TO HOUSE-IE. H2.5 OR A-35 5) SEE SD-4-14B FOR BLOCKING BETWEEN RAFTER DETAIL 6) NEED POST TO GIRDER HARDWARE ON PATIO 7) NAIL OFF SHEARWALL AT PATIO DOOR |