Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/28/2003 FRAMING Approved IVRS - Inspection 0000*
11/26/2002 FRAMING Denied IVRS - Inspection 0935*/ 1) RETRO FIT BOLTS MUST BE EPOXY SET NOT RED HEADS SEE PAGES S-1/S11 THIRD FAILURE (REFEE)
11/25/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) YOU MUST PROVIDE APPROVED ENGINEERING FOR RETRO FIT ANCHOR BOLTS 2) NEXT FAILURE WILL RESULT IN A REINSPECTION FEE
11/21/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) ITEMS 1 FROM 11/20/02 NOT COMPLIED WITH 2) ITEM 2 FROM 11/20/02 NOT COMPLIED WITH (LAUNDRY) 3) HOLDOWN NOT COMPLETE PROVIDE ENGINEERS AND CITY OF TUCSON APPROVED REPAIR
11/20/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) PER GENERAL NOTE: S1 ALL RETRO FIT ANCHOR BOLTS MUST BE EPOXY SET WITH SPECIAL INSPECTION 2) RECESSED LIGHTS MUST BE 12" FROM PEX 3) ANCHOR BOLTS LOOSE THROUGHOUT 4) BLOCKING PANELS NOT NAILED AT 3" ON CENTER PER 6/SD2 5) HOLDOWN MISSING L/R 6) MECH BOOT Y REQUIRES INSULATION-DUCT RESTRICTED 7) STRAP TRUSS BRACE PER 7/SD3 8) 2ND FLOOR SD