Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/28/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/26/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0935*/ 1) RETRO FIT BOLTS MUST BE EPOXY SET NOT RED HEADS SEE PAGES S-1/S11 THIRD FAILURE (REFEE) |
| 11/25/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) YOU MUST PROVIDE APPROVED ENGINEERING FOR RETRO FIT ANCHOR BOLTS 2) NEXT FAILURE WILL RESULT IN A REINSPECTION FEE |
| 11/21/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) ITEMS 1 FROM 11/20/02 NOT COMPLIED WITH 2) ITEM 2 FROM 11/20/02 NOT COMPLIED WITH (LAUNDRY) 3) HOLDOWN NOT COMPLETE PROVIDE ENGINEERS AND CITY OF TUCSON APPROVED REPAIR |
| 11/20/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PER GENERAL NOTE: S1 ALL RETRO FIT ANCHOR BOLTS MUST BE EPOXY SET WITH SPECIAL INSPECTION 2) RECESSED LIGHTS MUST BE 12" FROM PEX 3) ANCHOR BOLTS LOOSE THROUGHOUT 4) BLOCKING PANELS NOT NAILED AT 3" ON CENTER PER 6/SD2 5) HOLDOWN MISSING L/R 6) MECH BOOT Y REQUIRES INSULATION-DUCT RESTRICTED 7) STRAP TRUSS BRACE PER 7/SD3 8) 2ND FLOOR SD |