Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2003 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* | |
| 04/27/2003 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999* | |
| 02/09/2003 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*1.) YARDWATER CORRECTION REPLACE SLIP X FIP ADPT. WITH SLIPX MIP ADPT WITH EXFIP ADPT. | |
| 02/06/2003 | PLUMBING - ROUGH, SOIL | Partial Approval | 1.) YARDWATER PIPING TO FOX OK TO BE TESTED AT A LATER DATE. 2.) PVC FEMALE ADPT ARE NOT ALLOWED. |
|
| 02/04/2003 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*1.) ABS DWV UNDERGROUND OK WATER TEST OK 2.) 2" PVC YARDWATER FOR FOX FROM RPPBP TO TEE AT STAR OK TO COVER TO BE TESTED AT A LATER DATE. 3.) 1" PVC YARDWATER FOR STAR OK FROM METER TO BLDG. 4.) OK TO COVER SUBJECT TO REVISED PLANS. |