Permit: T02CM04968

Parcel: 134220030


Addresses:

6606 E LEHIGH DR

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
02/10/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
01/21/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :* WATER TEST 3" GREASE WASTE IN ? FROM SINK TO GREASE TRAP INLET CLEANOUT OK. 1) PROVIDE CORRECT MISSION COUPLING AT INLET AND OUTLET OF GREASE TRAP. 2) PERMANENT CAP OR REMOVE OLD FITTING ON INLET TO GREASE TRAP. 3" OUTLET FROM GREASE TRAP TO MAIN SEWER OK 2" VENT FROM GREASE TRAP THRU ROOF OK HCS CONNECTION OK. 3) PROVIDE LID EXTENSION FOR GREASE TRAP TO GRADE. PARTIAL APPROVAL PENDING NOTES #1, 2,3 CALL IN ALL UN APPROVED INSPECTIONS WITH FINAL.
01/04/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/1)PROVIDE AIR TEST ON ALL PIPING OR EXPOSE ALL PIPING FOR WATER TEST 2)EXPOSE DOWN STREAM OF GREASE INTERCEPTOR AT VENT AND TEST WITH AIR. 3)PROVIDE CORRECT LIP EXTENSION FOR GREASE INTERCEPTOR
12/20/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/1)REDLINES ON SITE. NO REVISED PLAN 2)NO PERMIT ON SITE
03/30/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*