Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM04949
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/20/2002 | FRAMING | Approved | IVRS - Inspection 0000*/ 1) COULD YOU RED LINE PLAN FOR A HEADER OF STUD MOVED SO DUCT DOESN'T CUT STUD EVERYTIME AT TUB BACK LIVING ROOM | |
12/19/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION STUD CUT UNDER TRUSS BEARING PT 2) YOU HAVE A 110 OUTLET IN FIREPLACE WITH A LOW VOLTAGE CONTROL WIRE, WHERE DOES THE POWER COME FROM 3) PIECE OF BACKING AT TUB MARKED ON FLOOR 4) DROP CEILING BLOCKS OVER ENTRY TO MASTER BEDROOM TOP OF WALL | |
12/18/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) CONNECTION AT FLOOR KITCHEN PONY WALL ELECTRIC, CONTINUE NON-METALLIC CONDUIT FROM FLOOR WITH A COUPLING, DIG OUT CONCRETE 2) STUD CUT FOR DIRECT VENT FIREPLACE 3) 110 OUTLET IN FIREPLACE NO POWER SOURCE 4) DIVERTER LEAK SOLDER JOINT HALL BATH 5) FLOOR OUTLET NOT COMPLETE 6) NO WATER IN DWV TEST 7) VERTICAL BACKING AT NORTH SHOWER 8) HORIZONTAL BLOCKS AT MASTER BEDROOM DROP FOR TOP PLATE NAILING 9) SUPPORT EXHAUST FAN DUCTS 10) #1 SHEAR WALL TRANSFER TO BE DONE PER (DETAILS 413-417) 11) GAS PRESSURE OK | |
12/17/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) ELECTRIC NOT COMPLETE 2) REPLACE STUD AT NON BEARING WALL 3) BLOCK MECHANICAL |