Permit: T02CM04948

Parcel: 141302110


Addresses:

10637 E MALTA ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM04948

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/19/2002 FRAMING Approved IVRS - Inspection 0000*
12/18/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) PROTECT WATER PEX AT THA STRAP, KITCHEN PONY WALL NAIL STRAP 2) SECURE PEX IN CEILING 12" FROM CAN LIGHT LIVING ROOM 3) ROMEX/IN LAUNDRY CEILING MISSING A BOX 4) STUD CUT TUB HALL BATH, B-WALL BREARING 5) BANG PLATE HALL BATH TOP PLATE PEX 6) GFCI OUTLET BOX MASTER BATH MISSING 7) REAR NB NOT INSTALLED 8) DAMPER MISSING MASTER BATH EXHAUST FAN 9) #1 SHEAR WALLS TO TRANSFER PEX 502/SD 10) GAS PRESSURE HOLDING