Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM04948
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/05/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
12/03/2002 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SEE LAST INSPECTION 2) MISSING WIND BRACING | |
12/02/2002 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NEED TRUSS DRAWING SORTED 2) 3 PT BEARING IN THIS HOUSE LOCATE BEARING PTS WITH TRUSS DRAWING DOUBLE TOP PLATE REQUIRED AND SHIM AT MIDDLE BEARING 3) FILL IN GAP AT REAR CC=OSB 4) SHEAR TO GO TO ROOF DECK 5) NAIL OFF PER SHEAR SCHEDULES |