Permit: T02CM04931

Parcel: 141171850


Addresses:

10356 E DANWOOD WY

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/17/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
12/12/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) SEE SHEAR TRANSFER DETAILS FOR #1 SHEAR AND IN GARAGE #1=14/DT1 2) MISSED 4' NAILING ON C.C. PLY ROOF EAST FRONT, MARKED IN BLACK 3) CHECK GABLE END BRACES
12/11/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) SAME AS LAST INSPECTION 2) NOT NAILED OFF