Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/24/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 11/19/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) WIND BRACING INCOMPLETE 2) STRAP EXTERIOR PLATES PLB/ELECT PENETRATIONS 3) REAR HOLDOWNS WRONG LOCATION 4) REAR PORCH MISSING 4 X 6 POST 5) REAR HOLDOWNS AT PORCH CALL FOR 4 X POSTS |