Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/07/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/06/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) FIRE STOP WATER HEATER 2ND FLOOR |
| 01/03/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) WATER HEATER VENT NOT FIRE STOPPED AT 2ND FLOOR CEILING |
| 01/02/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) #8 FROM 12/27/02 NOT COMPLETE ALL ELSE OK TO COVER |
| 12/30/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 12/27/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) HOLDOWN NORTH WEST NOT SECURE 2) SUPPORT JOIST ABOVE DEN HEADER 3) 2ND FLOOR SHEAR PLATE NOT NAILED 4) DOUBLE POST TRUSS TO GROUND 5) NO DWV WATER TEST 6) NAIL PROTECT K PEX 7) DUCT RESTRICTED BY NAILER 8) FIRE STOP WATER HEATER VENT AT FLOOR 9) NO CONDENSATE LINE |
| 12/24/2002 |
FRAMING |
|
Cancelled |
IVRS - Ri canceled |