Permit: T02CM04895

Parcel: 122180930


Addresses:

3608 E LEE ST #05

Inspection Status: Not ready for Inspection

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
05/01/2003 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*APPROVED EXTENDER RING ARE NEEDED AT CABINET.
2.) 2 CIRCUITS TO SERVE COUNTER TOPS AND GFCI PROTECTED
3.) GFCI NOT WORKING IN KITCHEN.
4.) GROUNDED RECEPTACLES ON UNGROUNDED CIRCUIT.
5.) CORD NOT ALLOWED FOR WATER HEAER ALSO A DISCONNECTING. MEANS IS NEEDED.
04/29/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*LOCKED RE FEE TO BE ISSUED 3RD TIME.
12/31/2002 ELECTRIC - FINAL Partial Approval UNIT #6. APPROVED #5 LOCKED.
12/27/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0245*THE WATER HEATERS ARE "FIXED APPLIANCES" AND CANNOT BE CORD CONNECTED. THESE UNITS MUST BE "HARD WIRED" TO THE ELECTRIC SYSTEM.
12/19/2002 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*OK TEMP C OF O. NEED TO BOND WATER PIPING.