Permit: T02CM04854

Parcel: 138212380


Addresses:

6782 S LEARY AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/26/2003 FRAMING Approved IVRS - Inspection 0000*
03/24/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) GROUND ALL METAL ELECTRIC BOXES 2) CONNECT ALL GROUNDS AND SECURE WITH A MECHANICAL FASTENER 3) LOCATION OF ELECTRIC SUB PANEL IS OBSTRUCTED. MUST HAVE A 30" X 30" WORK AREA IN FRONT OF PANEL WITH NOTHING BELOW PANEL. THE HEIGHT OF TOP CIRCUIT BREAKER CANNOT EXCEED 6'-6" 4) DRYER CIRCUIT AND WASHER CIRCUIT NOT IN 5) REVISE PLAN FOR ADDED OVERHANG OF PORCH 6) REVISE PLAN FOR LAUNDRY ELECTRIC-EXISTING PLUMBING OK 7) ELECTRIC OUTLET REQUIRED WITHIN 6' OF SOUTH DOOR
03/17/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*