Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/26/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/24/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) GROUND ALL METAL ELECTRIC BOXES 2) CONNECT ALL GROUNDS AND SECURE WITH A MECHANICAL FASTENER 3) LOCATION OF ELECTRIC SUB PANEL IS OBSTRUCTED. MUST HAVE A 30" X 30" WORK AREA IN FRONT OF PANEL WITH NOTHING BELOW PANEL. THE HEIGHT OF TOP CIRCUIT BREAKER CANNOT EXCEED 6'-6" 4) DRYER CIRCUIT AND WASHER CIRCUIT NOT IN 5) REVISE PLAN FOR ADDED OVERHANG OF PORCH 6) REVISE PLAN FOR LAUNDRY ELECTRIC-EXISTING PLUMBING OK 7) ELECTRIC OUTLET REQUIRED WITHIN 6' OF SOUTH DOOR |
| 03/17/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |