Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
| Date |
Description |
Inspector |
Results |
Comments |
| 10/29/2002 |
BUILDING PRE-SLAB |
|
Approved |
IVRS - Inspection 0000* |
| 10/25/2002 |
BUILDING PRE-SLAB |
|
Denied |
IVRS - Inspection 0999*/ 1) EXPOSE ALL FITTINGS FOR INSPECTION 2) YOU MUST HAVE A 10' HIGH WATERCOLUMN STACK FILLED TO TOP TO INSPECT ROUGH PLUMBING 3) FOR PRE-SLAB INSPECTION ALL PLUMBING THAT WILL BE IN CONTACT WITH CONCRETE MUST BE IN A SLEEVE OR BE FULLY PROTECTED WITH AN APPROVED CLOSET WRAP 4) REINFORCING STEEL MUST BE 3 INCHES FROM SOIL 5) REINFORCING STEEL SPLICES MUST HAVE 40 ROD DIAMETER ( 20 INCHES) OVERLAP 6) UFER GROUND WIRE MUST BE AT LEAST AT #4 COPPER WIRE CONNECTED TO REBAR WITH AN APPROVED UFER CLAMP. NOT AN ACORN CLAMP COPPER CANNOT BE IN CONTACT WITH STEEL |