Permit: T02CM04778

Parcel: 141303230


Addresses:

6454 S WHEATON DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM04778

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/11/2002 FRAMING Approved IVRS - Inspection 0000*
12/10/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION TRUSS DRAWINGS, MISSED TO MANY BEARING SUPPORTS, 3 PT INTERIOR 2) LAYOUT SHEET NOT CORRECT FOR THIS GARAGE 3) EXHAUST FAN NOT ATTACHED TO TRUSSES 4) 8/A8A SHEAR TRANSFER, NEED DETAIL SHOWING DROP CEILING 5) USED EXPANSION BOLTS FOR INTERIOR H.D.'S NEED PERMISSION FROM STRUCTUAL ENGINEER
12/09/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) VENTED FREEZE BOARDS CHECK PLANS(TRUSS CALC'S 2) NO SUPPLY WATER 3) NO WATER TEST DWV 4) TIGHTEN ALL ANCHOR BOLTS 5) WILL APPROVE FRAMING WHEN #1,2 AND 4 ABOVE ARE COMPLETED