Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM04773

Parcel: 141302240


Addresses:

10592 E MALTA ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM04773

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/13/2002 FRAMING Approved IVRS - Inspection 0000*
12/12/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) BOLTS IN HOLDOWNS IN DEN 2) ANCHOR BOLT SILL PLATE IN WEST WALL OF KITCEHN 3) MISSING PERIMETER NAILING AT SHED ROOF REPLACE WITH STRAPPING ON WEST SIDE 4) WATER ON ALL CROSS BRACING 5) MASTER BATH WATER CLOSET SUPPLY LINE. ROLL UP FITTING FOR TOILET VENT 2ND FLOOR TOILET ON SOUTH WALL 6) PROVIDE VARIANCE 7) SEAL INSIDE OF PLENUM UPSTAIRS FURNACE PLATFORM 8) COMPLETE FRAMING AROUND FRESH AIR SUPPLY 9) STRAP PEX PIPING IN MAIN BATH DOWNSTAIRS SO IT WILL NOT CONTACT DRYWALL OF CEILING 10) DAMPER IN EXHAUST FAN IN LAUDNRY ROOM IS DEFFECTIVE