| 11/19/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Approved |
IVRS - Inspection :* |
| 07/21/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :* |
| 07/06/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :* |
| 06/26/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :* |
| 06/18/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :*PARTIAL APPROVAL |
| 06/14/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :*/ 1) OK TO PLATE FTG-NORTH CLASSROOM WALL |
| 06/03/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :* |
| 06/02/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 05/28/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :*/ 1) OK TO 21'-8" AT GAME ROOM WEST WALL |
| 05/26/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :*/ 1) TOP OUT AT EAST WALL GAME ROOM 16'-8" AT WEST WALL SAME |
| 05/21/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :* |
| 05/16/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :*/ 1) OK NORTH WALL OF ROOM #101 EAST WALL #105-WEST WALL #105 |
| 05/12/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :* |
| 05/07/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :*/ 1) OK 8' AT 102-103 NORTH WALL |
| 05/05/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :*/ 1) SOUTHWALL ROOMS #111, 112 AND 113 16'/21'-4" AND 16'-18' AFF 2) SOUTH WALL CORRIDOR #104 15/17'-4" 3) WINDOW WALL/SCREEN WALL AT WEST PATIO #110, #200 4'-8' |
| 05/03/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :* |
| 04/21/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* EAST WALL TO MULTIPURPOSE |
| 04/16/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 04/15/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 04/14/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :* |
| 04/13/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* SOUTH CORRIDOR WALL |
| 04/09/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 04/08/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :* MULTI PURPOSE ROOM WEST WALL 12'-16' LIFT |
| 04/07/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* MULTI PURPOSE BUILDING |
| 04/05/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 04/02/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* SOUTH MULTI PURPOSE RM WALL @ 16'. BATHROOMS WEST WALL @ 12' |
| 03/31/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* 8' 0 BATHROOM- OFFICES, 12' 0 MULTI PURPOSE ROOM. SOUSTH WINDOW WALL OK TO POUR. |
| 03/25/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :* SOUTH WALL 8' EAST WALL 12' @ MULTI PURPOSE ROOM |
| 03/22/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* DRESSING RMS 4' & EAST MECH 4' LIFT |
| 03/18/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection :* 4' @ POOL ROOM & SOUTH MECH HALL |
| 03/11/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* OK TO 4 @ MULTI PURPOSE- BATHROOMS & OFFICES |
| 02/03/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 02/02/2004 |
REINFORCED MASONRY PRE-GROUT |
|
Not ready for Inspection |
IVRS - Inspection 0000* |