Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM04705
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/09/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000*/ 1) AT INTERMEDIATE CHECK (BOTH SIDES OF HOUSE) LEDGER NAILING 2) NEED HIP GIRDER TRUSS PAGE 3) FLOOR CUT FOR ? GARAGE WALL, WAS ANY REBAR CUT | |
12/06/2002 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION HIP ROOF NAIL PLYWOOD DECK TO 2 X 4 NAILER 2) SHEAR ADDED TO REACH ROOF, USE 8D NAILS NOT TECO'S 3) SHED ROOF ON EAST WALL DECK NOT NAILED TO LEDGER 4) ADD FILLER STRIPS AND NAIL WITH 16DS 5) CHECK LEDGER NAILING AT INTERMEDIATE 6) NEED CORRECT TRUSS LAYOUT PLAN FOR HIP GIRDER IN GARAGE 7) NEED CANTILLEVER DETAIL, NOT ON MAIN PLAN | |
12/05/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999* | |
12/02/2002 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) MISSING WIND BRACING 2) FRONT FRAMING POP OUT SUPPORT 3) SHEAR TO GO UP TO ROOF DECK 4) HIP GIRDER FOR EXTENTION NOT IN TRUSS PLANS 5) HIP ROOF WEST WALL NAIL SHEATHING TO 2 X 4 NAILS ATTACH ? TO WALL 6) ? ALL SHEAR TRANSFERS 7) RAT UNS FLOOR TRUSSES | |
11/27/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) STRAP NON-CABIN TIED TOP PLATES AT REAR CORNERS AND AT FRONT BAY 2) NAIL OFF SHEAR OSB AT MASTER SHOWER 3) FINISH CLIPPING ROOF LEDGER IN MASTER CLOSET 4) BLOCK AND NAIL SHORT OSB AT SOUTH WEST GARAGE HIP 5) LAG OUTSIDE PATIO ROOF LEDGER TO GIRDER |