Permit: T02CM04704

Parcel: 135076550


Addresses:

7842 E AINSWORTH DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM04704

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/14/2003 FRAMING Approved IVRS - Inspection 0000*
01/13/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) REPAIR WASTE PIPE LEAK IN DINING CEILING 2) SUPPORT 2 VENT 90 DEGREE IN REAR GARAGE WALL AND UPHALL BATH
01/08/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) NEED WATER PRESSURE AND DWV TEST 2) REPLACE GAS PRESSURE GUAGE 3) STRAP THE TOP CORD OF FLOOR TRUSS AT A/C PROTRUSION AND NAIL OFF OTHER STRAPS 4) SUPPORT VENT 90 DEGREE IN REAR GARAGE WALL AND HALL BATH CEILING 5) CORRECT GIRDER TO FLOOR TRUSS CONNECTION ABOVE KITCHEN SINK 6) BLOCK DUCT BOOTS UPSTAIRS 7) SUPPLY TRUSS DRAWINGS