Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM04659
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/27/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
11/23/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) BAY WINDOW ROOF LEDGER STILL NEED POSITIVE ATTACHMENT IE H2.5 OR A-35 PROPERLY INSTALLED FOR A LEDGER | |
11/20/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) BAY AND FRONT ROOF LEDGERS STILL HAVE NO PROPER ATTACHMENT WITH THE CLIPS INSTALLED 2) THE EXTERIOR PATIO ROOF LEDGER NEEDS TO BE LAGGED TO THE GIRDER | |
11/19/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) EAST SIDE OF ENTRY HIP IS NOT NAILED 2) SHINERS MISSED 5TH TRUSS BACK ON EAST SIDE 3) STRAP FRONT GABLE TRUSS DOWN AT EAST END AND STRAP TOP PLATES AT SAME PLACE 4) NO POSITIVE ATTACHMENT AT-BOTH PATIO RAFTER LEDGERS AND BAY ROOF LEDGERS 5) STRAP TOP PLATES AT SOUTH WEST CORNER 6) NO CONNECTION AT BAY TOP PLATES TO GABLE WALL 7) NO POSITIVE ATTACHMENT AT FRONT LOWER ROOF LEDGER |