Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/26/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/25/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) BLOCK 3 SIDES MECHANICAL VENTS 2) 1" CLEARANCE FLUE PIPES TO COMBUSTIBLES 3) LEAK AT WASHER 4) FIRE BLOCK ALL FURR DOWN AREAS 5) INSTALL COMB/RELIEF VENTS TOP AND BOTTOM UTILITY ROOM 6) PLAN CALLS FOR GAS FURNACE AND RANGE 7) INSTALL LONG SWEEPS KITCHEN VENT 90 DEGREE ELBOWS 8) STRAP ALL PLUMBING AND ELECTRIC HOLES WHERE NAILS MIGHT PENETRATE 9) GAS NOT INSTALLED PER PLAN 10) STOPPED INSPECTION 11) SUBMIT ASBUILT REVISIONS TO PLAN CHECK FOR APPROVAL |
| 09/04/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 08/26/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) STRAP ACCROSS BEAM SPLICES 2) FILL IN SOLIDLY UNDER BEAM BEARING 3) BEAM MISSING FRONT PORCH 4) INSTALL POSITIVE CONNECTION ALL BEAMS INTO MASONRY 5) NEED LADDER ACCESS TO INSPECT ROOF SHEATHING |