Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/20/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/19/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NEED CLIPS 8" ON CENTER ON TRUSS CHORD TO TOP PLATE IN BEDROOM 2 2) NUTS MISSING ON HOLDOWNS IN KITCHEN MARKED WITH REQUIRED X 3) DIAGONAL BRACING FRONT OF GARAGE NOT PER S1.1/11 MUST REST ON TOP OF DOUBLE TOP PLATE |
| 11/18/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) DIAGONAL BRACING AT FRONT OF GARAGE GABLE BRACING MUST BE TO TOP OF DOUBLE TOP PLATE PER DETAIL 2) SHEARWALLS 7 AND 8 TRUSS TO TOP PLATE CONNECTION REQUIRES A35'S EVERY 8" ON CENTER PER S1.1/14 |