Permit: T02CM04620


Addresses:

2218 N BELVEDERE AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/12/2002 FRAMING Approved IVRS - Inspection 0000*
11/08/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) CORRECT PITCH ON LAV ARM 2) SHIM CRIPPLES AND HEADERS SHERE NEEDED 3) NEED DWV TEST 4) FHA STRAP OVER ? ON BEARING PLATES
11/07/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE DWV WATER TEST PER UPC 712.2 2) NAIL PROTECT PLUMBING WITHIN 1 1/2" OF WALL/STUD SURFACE 3) DRYER VENT MUST EXHAUST OUTSIDE 4) FURNACE "B" VENT REQUIRES 1" CLEARANCE TO COMBUSTIBLES 5) A/C CONDENSATE DRAIN NOT IN 6) GAS TEST LESS THAN 10 PSI 7) STOPPED INSPECTION, TOO MANY ITEMS
11/06/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*
11/05/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION