Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM04619

Parcel: 11904037C


Addresses:

3515 S 7TH AV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/10/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
11/20/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PROVIDE DETAIL 4 AND 2 2) OK TO DRY IN
11/13/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PROVIDE A35 AND H2.5 AT ALL BRACES AT GABLES END TRUSS 2) HOLDOWN MISSING AT GARAGE 3) LOOSE SHEATHING AT ROOF