Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T02CM04617
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/04/2003 | BUILDING PRE-SLAB | Approved | IVRS - Inspection 0000*MISSING SECTION TO BE DONE ON TI PERMIT. | |
02/26/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*1ST FLOOR EXCEPT SE PEIWAY RESTAURANT. | |
02/21/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*MECH PAD ON ROOF OK TO POUR PENDING SPECIAL INSPECTION OF WELDS. | |
02/13/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*4TH FLOOR DECK OK, TO PLACE CONCRETE. | |
02/12/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*A.) SPECIAL INSP. REPORTS FOR WELDING/BOLTING OF 2ND, 3RD, 4TH, FLOORS REVIEWED, OK. STAIR AND ROOF NOT YET COMPLETE. 1.) 2ND FLOOR DECK OK TO POUR WHEN DEBRIS BLOWN OFF DECK. 2.) MAINTAIN MINIMUM 3/4 COVER FOR SLAB DOWELS @ EDGE. 3.) FINISH PLACING #3 X 10" BARS AT RE-ENTRY CORNERS. 4.) 3RD FLOOR DECK AND NELSON STUD WELDING COMPLETE. 5.) 4TH FLOOR DECK & STUD WELDING OK. REPAIR DAMAGED DECK SEAM @ A.5/3.5.3RD FLOOR DECK OK TO POUR. |
|
02/10/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*A.) SPECIAL INSP. REPORTS FOR WELDING/BOLTING OF 2ND, 3RD,4TH FLOORS REVIEWED, OK, STAIRS AND ROOF NOT YET COMPLETE. 1.) 2ND FLOOR DECK OK TO POUR WHEN DEBRIS BLOWN OFF DECK. 2.) MAINTAIN MINIMUM 3/4 COVER FOR SLAB DOWELS @ EDGE. 3.) FINISH PLACING 3X6 0" BARS AT RE-ENTRY CORNERS. 4.) 3RD FLOOR DECK AND NELSON STUD WELDING COMPLETE. 5.) 4TH FLOOR DECK & STUD WELDING OK. REPAIR DAMAGED DECK SEAM @ A.5/3.5 |