Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/12/2003 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* |
| 10/23/2002 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000*1.) PHASE THREE SECTION "D" COLUMN 6-H BREAKROOM SINK AND FLOOR DRAIN OK OK TO COVER. 2.) BREAKROOM SINK, AREA "C" COLUMN 6-G OK OK TO COVER. 3.) BREAKROOM SINK AT 6-F OK TO COVER TIE-IN AT EXISTING ONLY. NEED REVISED PLAN TO CONTINUE. |
| 10/21/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*1.) NO APPROVED PLAN ON SITE NEED DELTA ONE REVISION OR EQUIVILENT FOR 3 COMP SINK. HAVE PLANS STAMPED BY PLAN REVIEWER. 2.) HORIZONTAL VENTING BELOW FLOOD RIM LIMITED TO STRUCTURAL CONDITIONS. 3.) MINIMUM SIZE CLEAN OUT FOR 3" WASTE IS 2 1/2" 4. INDIRECT WASTE ON DISCHARGE SIDE OF GREASE TRAP IN QUESTION. |