Permit: T02CM04595

Parcel: 14029050A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
04/12/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
10/23/2002 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) PHASE THREE SECTION "D" COLUMN 6-H BREAKROOM SINK AND FLOOR DRAIN OK OK TO COVER. 2.) BREAKROOM SINK, AREA "C" COLUMN 6-G OK OK TO COVER. 3.) BREAKROOM SINK AT 6-F OK TO COVER TIE-IN AT EXISTING ONLY. NEED REVISED PLAN TO CONTINUE.
10/21/2002 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1.) NO APPROVED PLAN ON SITE NEED DELTA ONE REVISION OR EQUIVILENT FOR 3 COMP SINK. HAVE PLANS STAMPED BY PLAN REVIEWER. 2.) HORIZONTAL VENTING BELOW FLOOD RIM LIMITED TO STRUCTURAL CONDITIONS. 3.) MINIMUM SIZE CLEAN OUT FOR 3" WASTE IS 2 1/2" 4. INDIRECT WASTE ON DISCHARGE SIDE OF GREASE TRAP IN QUESTION.