Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/13/2003 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*/ 1) SOIL WATER TEST. 2)NOTE: BLDG DRAIN IS STUBBED OUT @ TWO WAY C.O. LOCATION ONLY. TWO WAY C.O. HAS NOT BEEN INSTALLED @ THIS TIME. |
| 08/12/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/1) MUST PROVIDE 10' OF HEAD OF WATER ON SANITARY SYSTEM SEE SECTION 712.2 - 94 UPC. |
| 08/11/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/1) MUST PROVIDE REVISED AND APPROVED DRAWING ON WASTE AND VENT SYSTEM ON SITE PRIOR TO ROUGH SOIL INSPECTION 2) DO NOT COVER. |