Permit: T02CM04588

Parcel: 14125001B


Addresses:

8133 S WILMOT RD


Inspection Status: Approved

Inspection History: STEM WALL/RETAINING WALL

Permit Number - T02CM04588

Inspection Description - STEM WALL/RETAINING WALL

Inspection Status - Approved

Date Description Inspector Results Comments
12/16/2003 STEM WALL/RETAINING WALL Approved IVRS - Inspection 0000*
10/02/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*
08/18/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*
08/04/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000* OK @ S W CORNER WALL A-G
07/30/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000* 1) BG RES WALL OK. 2) PER CONSERVATION REBAR FROM EXTERIOR TO INTERIOR FOOTING. (REF M3/23)
07/25/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000* A4 OK TO CLOSE & POUR
07/24/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) D6, A3 AND C6
07/23/2003 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection 0000*/ 1) 2:40 PM SITE LOCKED
07/21/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) ? STEEL-OK A3 AND A4 2) D6 OK TO POUR
07/18/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) STAIRS IN VALVE VAULT OK
07/17/2003 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection 0000*/ VALVE VAULT STAIR NOT READY. PLEASE COMPLETE TREAD FORMS, NOSE BARS AND POST INSERTS. 2) REINFORCEMENT FOR MATS DOES NOT CONFORM TO PLAN. IS THERE AN RFI OR DESIGN CHANGE?
07/16/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) A-2 CLOSED AND READY TO POUR 2) E-6 OK TO CLOSE AND POUR 3) ITEMS 2 (ABS FROM 7-2) WERE TAKEN CARE OF AND PLACEMENT OF CONCRETE OK PER BOB LENON OF TUCSON WATER 4) ITEM D FROM 7/2/03 HAS BEEN ADDRESSED IN RFI #39 DEGREE
07/09/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/1) OK TO CLOSE AND POUR A-1. 2) STEEL OK IN A-5, A-6, B-6. 3) PLEASE PROVIDE WRITTEN RE-INSPECTION REPORT FROM SPEC. INSP. CONCERNING ITEMS A,B,& C NOTED ON 7/2/03. 4) PLEASE PROVIDE ENGINEERING EVALUATION CONCERNING ITEM D FROM NOTES ON 7/2/03.
07/02/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000* 1. INSP OF DAMAGED VALVE VAULT AREA: A) #5 HOOKS AT TOP OF WALL HAVE NOT BEEN COMPLETED. B) OUTSIDE FACE OF REPAIR DOES NOT APPEAR TO COME TO TOP OF WALL. C) THERE ARE MISSING HORIZONTAL REINFORCEMENT BARS AT BOTTEM OF OUTSIDE FACE. D) YOU WILL NEED TO HAVE 2" CLEAR FROM VERTICALS TO FORM. I NOTICED THAT PART OF THE AREA YOU CHIPPED OUT ONLY HAS 1/2" OF COVER ON VERTICAL STEEL.
06/26/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) STEEL IN A2 AND E6 OK 2) READY TO CLOSE AND POUR SOUTH F6
06/23/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) STEEL IN F6 OK 2) F5 READY TO CLOSE AND POUR
06/18/2003 STEM WALL/RETAINING WALL Partial Approval 1) STEEL IN A1-OK
06/12/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) F-3 BLOCKED OUT AROUND VENTS 2) STEEL IN C6 AND D6 OK
06/09/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) I NEED SPECIAL INSPECTION REPORT FROM 6/6/03 2) STEEL OK IN D1, C1 AND F4 3) EXTRA REINFORCEMENT NEEDED FOR VENTS IN F-3
06/05/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000*/ 1) WALL AT TOP OF F2-OK 2) WALL AT TOP OF EL REQUIRES ADDITIONAL VERTICAL REINFORCEMENT PER DETAIL A/24. SPECIAL INSPECTOR IS ON SITE AIDING IN ADDITIONAL PLACEMENT. CONFIRMS ADDITIONAL VERTS.
05/30/2003 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection 0000* STAIRS IN RESERVOIR OK