Permit: T02CM04584

Parcel: 141305610

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM04584

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/10/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
12/09/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) SEE DETAILS ON, SHEAR WALL TRANSFER PANELS NAIL PER SCHEDULES IT'S IMPORTANT 2) BOUNDRY NAIL 2 X 4 BLOCKS AT REAR WALL, USE CORRECT SIZE BLOCKS
12/06/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION (DETAIL 4/SD4) NAIL PANEL TO ROOF, NAIL SIDE, BOTTOM AND TOP 2 X 4'S TO PLATES AND VERT. TRUSS MEMBERS 3" ON CENTER PER NAILING SCHEDULE, NAIL PLYWOOD TO BOX FRAME(NAIL PER DETAIL) ITEMS FROM LAST INSPECTION NOT DONE 7/SD3
12/04/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) SHIM ALL 3 PT BEARING PTS 2) INSTALL 1 X 4 MINIMUM LATERAL BRACE ON TRUSSES A-11 AT 1/2 PT 3) NEED BAY WINDOW STRAPED NOT CABIN TIED 4) NEED SHEAR PANELS AT MASTER BEDROOM OPTION SHEARWALL 5) SHEAR TRANSFER INSTALL PER DETAIL FLAT 2 X 8 6) LARGE CROSS BRACE BLOCK PEAK USE NAILS IN SHEAR SEE DETAIL 7/SD3
12/02/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) CABLES NOT PULLED