Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM04581
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/06/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
12/03/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) P-2 SHEAR NOT NAILED AT BANG PLATE 2) 1" CLEARANCE COMBUSTIBLES WATER HEATER FLUE2) DRYER DUCT OUT OF WALL 3) 2ND FLOOR TUB LEAKING 4) FLOOR BEARING PLATE CUT FOR 2" SOIL ACROSS FROM STAIRS 5) P-2 A-B 1'-4" ON CENTER 6) PEX 12" FROM CAN LITES LIVING ROOM 7) BANG PLATE LINE SETS 2ND FLOOR 8) BANG PLATE ROMEX 2ND FLOOR BEDROOM WALL STAPLE AT OUTLET BOX 9) CONENSATE NOT DONE 9) BLOCK AT 2ND FLOOR BATH WALL REVENT HOLE SIZE TO BIG FOR 2 X 4 10) GABLE BRACES TO BE STRAPED 11) GAS PRESSURE HOLDING |