Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/17/2007 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* | |
| 03/15/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE BACKFLOW PREVENTOR FOR LANDSCAPING 2. PROVIDE BACKFLOW CERTS. |
|
| 01/30/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* REVISED APPROVED PLAN ON SITE, INSTALL 2" FROM METER THRU 2" BACKFLOW DEVICE AND TIE IN TO 2" PVC CORRECTLY HAVE INSPECTION PRIOR TO COVERING AND PROVIDE BACKFLOW CERTIFICATION. |
|
| 12/20/2006 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* 1. INSTALL WATER PER APPROVED PLANS 2. PIPING INSTALLED YARD WATER WAS COVERED WITHOUT INSPECTION. |