Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/04/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1.) CORRECTION MADE OK 2.) OK FOR C OF O PENDING ANY OTHER INSPECTION. |
| 10/30/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) PROVIDE ROOF DRAIN WATER TEST 2.) SECURE PERMIT FOR GAS AND TEST TO 10# 3.) NO WATER HEATER. |
| 10/14/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) MUST USE APPROVED MATERIAL FOR ROOF DRAIN AND PUT RAIN LEADER UNDER WATER TEST. 2.) MUST PROVIDE OPEN FRONT SEATS ON ALL WATER CLOSETS. 3.)MUST CAP OFF ALL PLUMBING WASTE LINE EXTENDED OUT OF WEST EXTERIOR WALL NOT BEING USED. 4.) GAS LINE ON ROOF MUST BE BLOCKED UP 1 1/2" ABOVE ROOF EVERY 6'-0" AND STRAPED WITH APPROVED STRAPS. 5.) WILL REQUIRE A APPROVED PLAN ON RELOCATION OF WATER HTR & PLBG. SYSTEM PRIOR TO NEXT INSPECTION. |