Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM04559
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/12/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
12/11/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) BOLTS AT SHEARWALL 5 24" ON CENTER 2) RETRO FIT H.D. NEED EQUAL TO HPAD-22, MISSED AT EXT (EAST WALL) 3) BLOCK OFF RETURN PLENIUM 4) NAIL 16D'S AT 2ND FLOOR BOTTOM CHORD OF SHEAR TRANSFER, MISSED NAILING ON OSB 5) FINISH FRAMING AT RETURN 6) INSTALL H.D.'S BOLTS |