Permit: T02CM04559

Parcel: 141302360

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM04559

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/09/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) AT INTERMEDIATE CHECK FOR A) H.D. BOLT FOR MISSED P.A. EAST WALL B) STRAP ROOF AT SHED ROOF 2ND FLOOR WEST LEDGER NAILING NOT GOOD AT ROOF
12/06/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) FOR INTERMEDIATE INSPECTION CHANGE HANGER ON VAULTED TRUSS CHANGE LU210 TO LSS210
12/05/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SAME AS LAST INSPECTION, NOT DONE
12/02/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) FRONT 2ND FLOOR POP OUT FRAMING, NEED TO TALK TO CARPENTER, LOWER SUPPORT 2) MISSING 3 AT EAST GARGE 3) MISSED P.A. 5 EAST WALL 4) NORTH WEST CORNER 2ND FLOOR MISSED TO CS 16 STRAPS 5) ALL SHEAR TO GO TO ROOF DECK 6) WRONG HANGER VAULTED TRUSS DINNING ROOM 7) MISSED SHEAR TRANSFER #1 2ND FLOOR
11/29/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0950*/ 1) NO PLAN/PERMIT ON SITE
11/27/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) STRAP REAR UPPER TOP PLATES