Inspection Status: Not ready for Inspection
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/14/2002 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* 1) ELECTRICAL SERVICE WIRES FROM POWER POLE TO PT. OF ATTACHMENT ARE UNDER STRAIN FROM NEIGHBORING TREES. 2) OUTLET IN BEDROOM ADDITON TO REMAIN AN UNGROUNDED TYPE, OR INSTALL AGFCI 3) CHANGE FUSES IN A/C OT 50AMP. 4) ONLY TWO WIRES IN FEEDER TO HVAC USING CONDUIT AS A BOND TO GROUND, IT IS'NT CONNECTED IN PLACES 5) GAS PIPE NOT TO BE INGROUND ON WEST SIDE 6) EAST SIDE REQUIRES 1HR PROTECTION, WAS WEST SIDE EXEMPT BY PLANCHECK 7) ELECTRICAL SERVICE HAS MORE THAN SIX SWITCHES REQS A BACKFIELD BREAKER AT MAIN, WITH HOLD DOWN KIT. |
| 10/11/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999* |
| 10/10/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0945* |