Permit: T02CM04555

Parcel: 126171340


Addresses:

3937 E PASEO DORADO

Inspection Status: Not ready for Inspection

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/14/2002 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000* 1) ELECTICAL SERVICE WIRES FROM POWER POLE TO PT. OF ATTACHMENT ARE UNDERSTRAIN FROM NEIGHBORING TREES. 2) OUTLET IN BEDROOM ADDITON TO REMAIN AN UNGROUNDED TYPE, OR INSTALL AGFCI. 3) CHANGE FUSES N A/C TO 50AMP. 4) ONLY TWO WIRES IN FEEDER TO HVAC. USING CONDUIT AS A BOND TO GROUND, IT ISN'T CONNECTED N PLACES 5) GAS PIPE NOT TO BE IN GROUND ON WEST SIDE. 6) EAST SIDE REQUIRES 1HR PROTECTION, WAS WEST SIDE EXEMPT BY PLAN CHECK. 7) ELECTRICAL SERVICES HAS MORE THAN SIX SWITCHES REQS A BACKFLED BREAKER AT MAIN, WITH HOLD DOWN KIT.
10/11/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) PAPERWORK FROM PREVIOUS INSPECTION MUST BE PRESENT FOR THIS INSPECTION TO OCCUR
10/10/2002 BUILDING - FINAL Denied IVRS - Inspection 0945*