Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/05/2004 | FRAMING | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 11/12/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF STUD SURFACE 2) FIRE PLACE CHIMNEY MUST EXTEND 2 FEET HIGHER THAN ROOF WITHIN 10 FEET | |
| 11/07/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF STUD SURFACE 2) BLOCK MECHANICAL DEFUSER BOOTS 3 SIDES 3) ISOLATE ALL COPPER FROM GALVANIZED STUDS 4) FURNACE 'B' VENT INSTALLED UP SIDE DOWN | |
| 08/08/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ FRAME SO FAR MEETS PLAN AND CODE BUT WE CANNOT INSPECT OR APPROVE UNTILL ALL PLUMBING, ELECTRIC, GAS AND MECHANICAL ARE COMPLETE, AND PASSED INSPECTION. FOR ALL INTERMEDIATE INSPECTION ITEMS USE INSPECTION CODE 00035. |